Applications

System 6 Digital Torque Testers are excellent for:

  • Testing non-impacting power tools (stall, clutch, pulse)
  • Testing torque on rotating components and assemblies
  • Use when a broad range of torques will be encountered

Features and Characteristics

  • Connects with any of seven capacities of rotary torque transducers
  • Up to five torque transducers may be calibrated into tester
  • Accuracy of 0.5% of Indicated Value from 10% to 100% of transducer capacity
  • Simple to use
  • Four modes of operation: Track, Peak, Initial Peak, Power Tool
  • Large backlit display permits use in all lighting conditions.
  • Includes FREE certificate of calibration for each transducer calibrated into the system from our ISO/IEC 17025 Accredited Calibration Laboratory!
Part Number and Ordering Information
Part No. Model Description
10101 System 6-AC 120 System 6 w/120 VAC line operation
10102 System 6-AC 240 System 6 w/240 VAC line operation*
10096 6 Ft. RTT Cable RTT Transducer to System 6 cable, 6 feet long
10104 30 Ft. RTT Cable RTT Transducer to System 6 cable, 30 feet long
10105 50 Ft. RTT Cable RTT Transducer to System 6 cable, 50 feet long
* Requires special power cable. For cable descriptions and part numbers contact Customer Service
Additional Technical Information
Measurement  
Accuracy @ 72 deg. F (22 deg. C) 0.25% Indicated Value
Accuracy Range 10% - 100% of Transducer Capacity
System Resolution 4.5 digits
Resolution A/D Convertor 1/65,536
Conversion Rate 100kHz
Signal to Noise Ratio 78 dB
Physical  
Weight, AC Models 4.3 lbs. (2.0 Kg)
Dimensions 3.375” (96mm) H x 7.56” (192mm) W x 8.64” (220mm) D
Display 1 line x 16 characters, 0.5” (12.7mm) high characters, backlit LCD
Keyboard Membrane Switch Panel
Enclosure Aluminum, plastic bezel, meets MIL-T-28800E, Type 5, Class E specifications
Transducer Interface MS3102A 18-01S Amphenol
Serial Port RS 232C, set for 4800 baud/n/1 with ASCII handshake
Other Characteristics
Operating Temperature Range 32 deg. F to 125 deg. F (0 deg. C to 51.6 deg. C)
Storage Temperature Range -80 deg. F to 160 deg. F (-26.7 deg. C to 71.1 deg. C)
Storage Humidity Maximum 95% non-condensing
Line Voltage/Frequency 120 or 240 VAC, 50 or 60 Hz
Serial Interface RS 232C
Baud Rate Selectable for 300/1200/2400/4800/9600/19200, 4800 default from factory
Stop Bits 1
Parity Selectable for even/off/none/stick/mark, factory default is none
Connector DB9 female
Handshake None, ASCII text
Classification ASME B107.29M, Type 2, Class B